New! Seamless Integration of multi-vendor systems, devices, protocols
Protocol Converter, Data Logger, Web Interface with virtual HMI - all in one box
The Vlinx ConnectPro provides the functionality of a powerful Protocol Converter, a Data Logger, and a Virtual HMI and Ethernet Gateway all in one package. With three built-in serial ports and a 10/100 Base-TX Ethernet port, the unit performs protocol conversion, allowing disparate devices to communicate seamlessly with one another. The Ethernet port supports up to four protocols simultaneously so even Ethernet to Ethernet conversion may be performed. The CompactFlash card slot allows new configuration files to be created at a central location and distributed to units installed in the field easily. The USB port may be used for blazing fast file downloads, or to mount an installed CompactFlash card as an external drive to your PC. DIN rail mounting saves time and panel space and snaps easily onto standard top hat (T) profile DIN rail.
The VFG2000 and VFG3000 offer several additional features beyond those offered by the VFG1000. The CompactFlash card slot allows data to be collected and stored for later review. The files are stored in simple CSV file format allowing common applications, such as Microsoft Excel and Access, to view and manage the data. The free Websync utility provides a means to synchronize the files with a PCs hard drive for permanent storage.
The built-in Web server allows log files to be retrieved manually, and also provides access to the unique "Virtual HMI". Any standard Web browser such as Internet Explorer or Netscape may be used to monitor or control the HMI from a PC anywhere in the world.
- Protocol Conversion - Converts Numerous Protocols Simultaneously
- Extensive Built-In Driver List Allows Easy Mapping to PLC's, PC's, and SCADA Systems
- 10Base-T/100Base-Tx Ethernet Port Support 4 Simultaneous Protocols
- Independent Serial Ports Provide Virtually Unlimited Integration Methods
- CompactFlash ® Slot Allows Process Data to be Logged Directly to CSV Files (VFG2000 & VFG3000)
- Virtual HMI Offers Built-in PC-based SCADA Functionality (VFG2000 & VFG3000)
- Webserver Provides Worldwide Access To Data Logs And Virtual HMI (VFG2000 & VFG3000)
- Alarm Notifications can be sent via Email or Text Messages (VFG2000 & VFG3000)
Protocol Conversion
Everyone struggles with connectivity issues. Whether it's the PLC, servo, the barcode scanner, or the sensor with a serial output, something will communicate with a protocol that differs from the rest of the components in the system. The Vlinx ConnectPro solves these connectivity issues.
Data Logger
Everyone is trying to improve productivity. To do this, data needs to be gathered, stored, and analyzed. Many SCADA systems can do this. However, the cost and complexity proves prohibitive in many applications. The Vlinx ConnectPro Gateway not only collects the required data, it provides it in a format ready to be used. VFG2000 and VFG3000 offer additional features beyond VFG1000. A CompactFlash card slot allows data to be collected and stored in simple CSV file format allowing common applications, such as Microsoft Excel and Access, to view and manage the data later. Free Websync utility helps sychronize the files with a PC's hard drive for permanent storage.
Virtual HMI
Everyone is interested in lowering costs. Having the ability to know what a process or machine is doing and being able to modify that system from a remote location saves time and travel costs. The Vlinx ConnectPro's virtual HMI and Ethernet gateway provides advanced remote support capability to any machine.
Here is a sample of the vast protocol library supported by the Vilinx Connectpro
| BACnet 802.3 | BACnet MS/TP |
| BACnet UDP/IP | CANOpen |
| Device Net | Ethernet/IP |
| Encapsulated Modbus over Ethernet | Modbus TCP/IP |
| Modbus RTU | Modbus ASCII
| ProfiBus | |
Complete Protcol List
|  : | Good | Better | Best |
| Model Number | VFG1000 | VFG2000 | VFG3000 |
| Protocol Conversion | Multiple Serial and Ethernet Protocols |
| Virtual HMI | NO | QVGA (320x240) | VGA(640x480) |
| Data Logging | NO | YES |
| Onboard SDRAM | 2 Mb | 8 Mb |
| Input Power | 24 VDC |
| Mounting | 35mm DIN Rail |
| Operating Temperature | 0 to 50 C |
| Approvals | CE, FCC, UL, Class 1 Div 2 |
| Programming Port | USB 1.1 (type B) and RS-232 (RJ-12) |
| Serial Communications Port | RS-232 (RJ-12) and RS-422/485 (RJ-45) |
| Ethernet Port | 10Base-T, 100Base-TX (wired as NIC), RJ-45 |
| Onboard Non Volatile Memory | 4 Mb |
Vlinx Fieldbus Gateway
Vlinx Fieldbus Gateway - Protocol Converter, Data Logger, and Web Interface
|
Model No. |
Description |
Price |
VFG1000
|
|
|
VFG2000
|
|
|
VFG3000
|
|
|
Expansion Cards
Model No. |
Description |
Price |
VFG9000-CAN
|
|
|
VFG9000-CEL
|
GSM/GPRS Modem Card for Vlinx Fieldbus Gateway The functions of this option card are only accessible with the ConnectPro Versions VFG2000 and VFG3000
Datasheet / Quick Start Guide
Photo
|
|
VFG9000-DN
|
|
|
VFG9000-PBDP
|
|
|
VFG9000-SERIAL
|
|
|
Cables
| Model Number |
Description |
Connector |
|
Price |
| USBAMBM-6F
|
USB Programming Cable |
USB A to USB B |
|
| Qty 1-9: | $9.00 |
| Qty 10-19: | $8.55 |
| Qty 20-49: | $8.10 |
| Qty 50-99: | $7.88 |
| Qty 100+: | $7.65 |
|
|
| CBL01500
|
RS-232 Programming Cable |
RJ-12 to DB9F |
|
|
| CBL00100
|
Allen Bradley SLC 500 via DF-1 |
RJ-12 to DB9F |
|
|
| CBL00101
|
Allen Bradley PLC-5 via Channel 0 |
RJ-12 to DB25M |
|
|
| CBL00102
|
Allen Bradley SLC 500 via DH485 |
RJ-45 to RJ-45 |
|
|
| CBL00200
|
GE Fanuc 90 series via SNP |
RJ-45 to DB15M |
|
|
| CBL00301
|
Generic RS-232 |
RJ-12 to DB9M |
|
|
| CBL00302
|
Generic RS-232 |
RJ-12 to Bare Wires |
|
|
| CBL00303
|
Generic RS422/485 |
RJ-45 to Bare Wires |
|
|
| CBL00400
|
IDEC Micro 3 Series Mini |
RJ-45 to Mini-DIN 8 |
|
|
| CBL00401
|
IDEC Micro 3C Series Mini |
RJ-12 to Mini-DIN 8 |
|
|
| CBL00402
|
IDEC MicroSmart Series Mini |
RJ-12 to Mini-DIN 8 |
|
|
| CBL00500
|
Keyence KV Series |
RJ-12 to RJ-11 |
|
|
| CBL00600
|
Koyo Model 2xx |
RJ-12 to RJ-12 |
|
|
| CBL00700
|
Matsushita FP Series |
RJ-12 to DB9M |
|
|
| CBL00701
|
Matsushita FP0 Mini |
RJ-12 to Mini-DIN 5 |
|
|
| CBL00800
|
MODEM |
RJ-12 to DB9M |
|
|
| CBL00801
|
MODEM |
RJ-12 to DB25M |
|
|
| CBL00900
|
Mitsubishi FX Series |
RJ-45 to DB25M |
|
|
| CBL00901
|
RJ-45 to Mitsubishi FX0 and FX0N |
Mini-DIN 8 |
|
|
| CBL00902
|
Mitsubishi A Series via A1SJ71C24-R2 Module and Q Series via QJ71C24 Module |
RJ-12 to DB9M |
|
|
| CBL01000
|
Modicon RS-232 |
RJ-12 to DB9M |
|
|
| CBL01100
|
Miltitech Modems |
RJ-12 to DB15M |
|
|
| CBL01200
|
Omron RS232 |
RJ-12 to DB9M |
|
|
| CBL01201
|
Omron Sysmac C200H via LK210 Module |
RJ-12 to DB25M |
|
|
| CBL01202
|
Omron C-series |
RJ-45 to DB9M |
|
|
| CBL01700
|
Siemens S7 via PPI and Simovert via USS |
RJ-45 to DB9M |
|
|
| CBL01701
|
Siemes S7 via MPI Adapter (proprietary adapter not included) |
RJ-12 to DB9F |
|
|
| CBL01702
|
Siemes S7 via MPI Adapter (proprietary adapter included) |
RJ-12 to DB9F |
|
|
| CBL01703
|
Siemens (Texas Instruments 545) on Port 1 |
RJ-12 to DB9M |
|
|
| CBL01704
|
Siemens 545/555 via RS-232 |
RJ-12 to DB9F |
|
|
| CBL01705
|
Siemens 545/555 via RS-422 |
RJ-45 to DB9M |
|
|
| CBL01706
|
Siemens (Texas Instruments 500 Series) |
RJ-45 to DB9M |
|
|
| CBL01707
|
Siemens via CP525 Communication Card |
RJ-45 DB15M |
|
|
| CBL01708
|
Siemens S5 via AS511 |
RJ-12 to Proprietary |
|
|
| CBL01800
|
Telemecanique Unitelway Master |
RJ-45 to Mini-DIN 8 |
|
|
| CBL01801
|
Telemecanique Unitelway Slave Mini |
RJ-45 to Mini-DIN 8 |
|
|
| CBL02000
|
Yaskawa SMC3010 |
RJ-12 to DB9F |
|
|
| CBL02001
|
Yaskawa FSP Drive |
RJ-12 to Mini-MDR |
|
|
Note: All Cables are 10 Feet in length
|