Home
> Products > Wireless > Modular, Customizable Wireless I/O |
 |
Modular, Customizable Wireless I/O
Modules flexible enough to fit your application
| Features | Benefits |
| DIN Rail Package | Easy installation, conserves panel space (versus panel mount modems). |
| 3 Ranges Available | Short, Medium, Long range. Don’t spend more money on longer distance radios if you don’t need the distance. |
| Active Repeaters | Place I/O modules where they need to go, by the sensors. With repeater built-in functionality, you can build up a security path for all your critical communications. |
| Modular | Customize it to your application. Just snap on your I/O and you're ready to go. |
| 10-48 VDC Power Input | Rugged input power circuit allows insertion to most control power configurations. Can utilize industrial power supply. |
| Wide Temperature-Industrial Grade | Meets most indoor or outdoor applications. Rugged circuitry prevents signal degradation versus lower temperature rated wireless devices.(-40°-80° C) |
| Modbus Compatible | Interface using industry standard Modbus protocol. Connect to Wonderware, Labview or any other Modbus compatible software. Allows data to be directly brought into most PLC systems. |
Additional Features
- Automatic I/O mapping for wire replacement applications
- Transmission
FHSS - Frequency hopping spread spectrum on MR and LR
DSSSS - Direct sequence spread spectrum on SR
- Frequency - ISM band, 2.400 to 2.4385 GHz
- Modulation -FSK, Frequency shift keying
- Antenna - Reverse polarity SMA 2.1dB _ wave dipole (included)
- Easy Installation
LEDs for wireless links and local bus communication
Signal strength indicators for easy placement
- Free programming software
V3.0.0 Software
|
How to Select the Right System for you:
1. Determine if Wire Replacement (Peer-to-Peer) or Modbus Application (Peer to Multi-Peer).
Peer-to-Peer Mode – Inputs automatically map to the outputs! Simplify your installation by sending your digital and analog inputs and outputs over the air. Why run a
wire when you can install a Zlinx wireless module to replace it? The new Zlinx wireless product line provides point-to-point communication, replacing your wires. With bidirectional
flow control, the controllers allow full-duplex transmissions to optimize the communication efficiency. Modbus Mode – Up to 150 base modules in a system;
up to 6 systems can run simultaneously by using different RF network I/O.

|
2. Choose a Wireless Base Module.
Based on your wireless distance and
your I/O needs, select the right base for
you. Note: each range will only talk to
the same range (i.e. MR will only communicate
with MR, etc.).
| Digital Inputs (DI) | 0-48 VDC | ----- |
| Digital Outputs (DO) | 10-45 VDC | NPN, PNP, Relays |
| Analog Inputs (AI) | 4-20 mA, 0-20 mA or 0-10 VDC | Selectable in software |
| Analog Outputs (AO) | 4-20 mA, 0-20 mA or 0-10 VDC | Selectable in software |
| RTD Temp Inputs (AI) | PT100, PT1000, CU | Selectable in software |
|
|
| Model Number |
Frequency |
Radio Power |
RF Range (indoor/outdoor with included antenna) |
I/O DI/DO/AI/AO |
Digital Output |
|
Price |
| ZZ24D-NA-SR
|
2.4 GHz |
100 mW |
Up to 300 ft/Up to 1 mi |
2/2/2/2 |
PNP (sourcing) |
|
|
| ZZ24D-NB-SR
|
2.4 GHz |
100 mW |
Up to 300 ft/Up to 1 mi |
4/4/0/0 |
PNP (sourcing) |
|
|
| ZZ24D-NC-SR
|
2.4 GHz |
100 mW |
Up to 300 ft/Up to 1 mi |
2/2/2/2 |
NPN (sinking) |
|
|
| ZZ24D-ND-SR
|
2.4 GHz |
100 mW |
Up to 300 ft/Up to 1 mi |
4/4/0/0 |
NPN (sinking) |
|
|
| ZZ24D-NA-MR
|
2.4 GHz |
50 mW |
Up to 600 ft/Up to 3 mi |
2/2/2/2 |
PNP (sourcing) |
|
|
| ZZ24D-NB-MR
|
2.4 GHz |
50 mW |
Up to 600 ft/Up to 3 mi |
4/4/0/0 |
PNP (sourcing) |
|
|
| ZZ24D-NC-MR
|
2.4 GHz |
50 mW |
Up to 600 ft/Up to 3 mi |
2/2/2/2 |
NPN (sinking) |
|
|
| ZZ24D-ND-MR
|
2.4 GHz |
50 mW |
Up to 600 ft/Up to 3 mi |
4/4/0/0 |
NPN (sinking) |
|
|
| ZZ9D-NA-MR
|
900 MHz |
100 mW |
Up to 1500 ft/Up to 7 mi |
2/2/2/2 |
PNP (sourcing) |
|
|
| ZZ9D-NB-MR
|
900 MHz |
100 mW |
Up to 1500 ft/Up to 7 mi |
4/4/0/0 |
PNP (sourcing) |
|
|
| ZZ9D-NC-MR
|
900 MHz |
100 mW |
Up to 1500 ft/Up to 7 mi |
2/2/2/2 |
NPN (sinking) |
|
|
| ZZ9D-ND-MR
|
900 MHz |
100 mW |
Up to 1500 ft/Up to 7 mi |
4/4/0/0 |
NPN (sinking) |
|
|
ZZ9D-NA-LR
|
900 MHz |
1mW to 1W (selectable) |
Up to 3000 ft/Up to 14 mi |
2/2/2/2 |
PNP (sourcing) |
|
|
| ZZ9D-NA-LR-AU
|
900 MHz |
1mW to 1W (selectable) |
Up to 3000 ft/Up to 14 mi |
2/2/2/2 |
PNP (sourcing) |
|
|
| ZZ9D-NB-LR
|
900 MHz |
1mW to 1W (selectable) |
Up to 3000 ft/Up to 14 mi |
4/4/0/0 |
PNP (sourcing) |
|
|
| ZZ9D-NB-LR-AU
|
900 MHz |
1mW to 1W (selectable) |
Up to 3000 ft/Up to 14 mi |
4/4/0/0 |
PNP (sourcing) |
|
|
| ZZ9D-NC-LR
|
900 MHz |
1mW to 1W (selectable) |
Up to 3000 ft/Up to 14 mi |
2/2/2/2 |
NPN (sinking) |
|
|
| ZZ9D-NC-LR-AU
|
900 MHz |
1mW to 1W (selectable) |
Up to 3000 ft/Up to 14 mi |
2/2/2/2 |
NPN (sinking) |
|
|
| ZZ9D-ND-LR
|
900 MHz |
1mW to 1W (selectable) |
Up to 3000 ft/Up to 14 mi |
4/4/0/0 |
NPN (sinking) |
|
|
| ZZ9D-ND-LR-AU
|
900 MHz |
1mW to 1W (selectable) |
Up to 3000 ft/Up to 14 mi |
4/4/0/0 |
NPN (sinking) |
|
|
***Please Note: At least one programming cable, ZZ-PROG1 or ZZ-PROGKIT, is required for these modules. ***Models ending in -AU are Australian approved
3. Choose I/O Modules to Expand
Each base module allows up to 6 expansion
units using the following modules.
| Digital Inputs (DI) | 0-48 VDC | ----- |
| Digital Outputs (DO)* | 10-45 VDC | NPN, PNP, Relays |
| Analog Inputs (AI) | 4-20 mA, 0-20 mA or 0-10 VDC | Selectable in software |
| Analog Outputs (AO) | 4-20 mA, 0-20 mA or 0-10 VDC | Selectable in software |
| RTD Temp Inputs (AI) | PT100, PT1000, CU | Selectable in software |
*Sinking (NPN) available upon request.
|
|
| Model Number |
Digital Inputs |
Digital Outputs |
Analog Inputs |
Analog Outputs |
|
Price |
ZZ-8DI-DC
|
8 |
---- |
---- |
---- |
|
|
| ZZ-8DO-T
|
---- |
8* PNP (Sourcing) |
---- |
---- |
|
|
| New! ZZ-8DO-T1
|
---- |
8* NPN (Sinking) |
---- |
---- |
|
|
| ZZ-4DI4DO-DCT
|
4 |
4* PNP (Sourcing) |
---- |
---- |
|
|
| New! ZZ-4DI4DO-DCT1
|
4 |
4* NPN (Sinking) |
---- |
---- |
|
|
| ZZ-4AI
|
---- |
---- |
4 |
---- |
|
|
ZZ-4AO
|
---- |
---- |
---- |
4 Passive source, requires isolated external power supply |
|
|
| New! ZZ-4AO-2
|
---- |
---- |
---- |
4 Active source, no external power supply required |
|
|
| ZZ-2AI2AO
|
---- |
---- |
2 |
2 |
|
|
| ZZ-8DO-R
|
---- |
8** |
---- |
---- |
|
|
New! ZZ-4RTD1
|
---- |
---- |
4*** |
--- |
|
|
*T=Transistor **R=Relay
4. Choose a Radio Modem (if using Modbus System - see diagram #2 & #3 above)
Get your data signals moving faster, farther, easier and cheaper.
- DIN rail mount saves panel space.
- Constant signal strength feedback - during installation and troubleshooting later.
- Rugged circuitry, wide temperature - for indoor and outside applications.
- Handles most industrial control power configurations and power supplies.
- Immediate integration into UL, CSA approved panels.
Use the table to make sure the
radio modem is compatible with
your chosen base module. More details on
radio modems from B&B Electronics.
| Base Module | Radio Modem Required |
| ZZ24D-NA-SR | ZP24D-250RM-SR |
| ZZ24D-NB-SR | ZP24D-250RM-SR |
| ZZ24D-NA-MR | ZP24D-96RM-MR |
| ZZ24D-NB-MR | ZP24D-96RM-MR |
| ZZ9D-NA-MR | ZP9D-96RM-MR |
| ZZ9D-NB-MR | ZP9D-96RM-MR |
| ZZ9D-NA-LR | ZP9D-115RM-LR |
| ZZ9D-NB-LR | ZP9D-115RM-LR |
|
|
5. Choose Software and Accessories to complete your system.
Features
- New! Simplified programming software
- Basic screen and an advanced screen
- Auto search function if radio settings are forgotten
- Easy field firmware updates
Easy-to-program system! Zlinx radio modems and Zlinx Modbus I/O use the same software manager suite.
Configuration software is free (download software).
Or a CD can be purchased -- absolutely no registration fees or worries about installing it on any computer you have. |
Model No. |
Description |
Price |
DR-120-24
|
|
List Price: $99.00
Sale Price: $79.20
20% off through 12/31/09
|
|
New! ZZ-DIN1
|
Zlinx Modbus I/O - Spare DIN Mount Clip, Spring, 4 Screws
|
|
ZZ-PROG1
|
|
|
ZZ-PROGKIT
|
|
|
New! ZZ-TB1
|
Zlinx Modbus I/O - Spare Terminal Block Kit, Dip Switch Cover
|
|
New! ZZ24D-ANT1
|
Zlinx Modubs I/O - Spare Antenna, 2.4 GHz
|
|
New! ZZ9D-ANT1
|
Zlinx Modbus I/O - Spare Antenna, 900 MHz
|
|
|
|
 |