Home
> Products > Wireless > Zlinx Wireless I/O |
 |
Zlinx™ Wireless Modbus I/O - Faster and Better than Ever
New Features Include:
- Improved Latency - Very low I/O latency allows real time control and monitoring.
- Exception Reporting - In Modbus mode, allows the reporting of possible problems with connected devices.
- Fail Safe - Allows you to set your I/O to a safe state in the event of a communication failure.
- Calibration - Calculates correction factors to make I/O values more accurate or to better match a sensor.
- Communications Failure Alarm - Allows the first DO to be configured as a COM failure alarm indicator.
- Peer-to-Peer I/O Configuration - One to one I/O mapping of 2 identical systems. Allows remote control of analog and digital I/Os.
- Inverter Outputs - Allows flexibility in the logic to control output devices.
- Monitor - You can use the Zlinx Manager Software to monitor your I/O.
Add Wireless I/O to Any Modbus System
- Connects directly to analog, digital and temperature inputs and outputs
- Point to point/multi-point wire replacement
- Exandable, modular design
- Modbus compatible
Modbus Appliction (Peer to Multi-Peer)
Seamlessly add wireless I/O to any Modbus application. Modbus is the most widely supported I/O protocol worldwide for PLC's to HMI's and PC based software applications. With Zlinx Wireless I/O you can now bring wireless remote I/O into any Modbus system. Simply connect a Zlinx modem to an RS-232 or RS-485 port of the Modbus master and it can now poll up to 150 wireless I/O notes - each node can be configured for 8 to 48 I/O points.
Step 1. Choose a Wireless Base Module.
Step 2. Choose I/O Modules to Expand.
Step 3. Choose a Radio Modem
Step 4. Choose Software and Accessories to complete your system.

|
Step 1. Choose a Wireless Base Module.
Based on your wireless distance and
your I/O needs, select the right base for
you. Note: each range will only talk to
the same range (i.e. LR will only communicate
with LR, etc.).
| Digital Inputs (DI) | 0-48 VDC | ----- |
| Digital Outputs (DO) | 10-45 VDC | NPN, PNP, Relays |
| Analog Inputs (AI) | 4-20 mA, 0-20 mA or 0-10 VDC | Selectable in software |
| Analog Outputs (AO) | 4-20 mA, 0-20 mA or 0-10 VDC | Selectable in software |
| RTD Temp Inputs (AI) | PT100, PT1000, CU10 | Selectable in software |
|
| Model Number |
Frequency |
Radio Power |
RF Bandwidth |
RF Range Supplied Antenna (indoor max/ outdoor max) |
RF Range High Gain Antenna (outdoor max) |
Latency analog, digital (note 1) |
I/O DI/DO/AI/AO |
|
Price |
| ZZ24D-NA-SR
|
2.4 GHz |
10 mW (Europe), 63 mW (rest of world) |
250 Kbps |
Up to 300 ft/Up to 1 mi |
-- |
15, 8 mS |
2/2/2/2 PNP (Sourcing) Digital O/Ps |
|
|
| ZZ24D-NB-SR
|
2.4 GHz |
10 mW (Europe), 63 mW (rest of world) |
250 Kbps |
Up to 300 ft/Up to 1 mi |
-- |
15, 8 mS |
4/4/0/0 PNP (Sourcing) Digital O/Ps |
|
|
| ZZ24D-NC-SR
|
2.4 GHz |
10 mW (Europe), 63 mW (rest of world) |
250 Kbps |
Up to 300 ft/Up to 1 mi |
-- |
15, 8 mS |
2/2/2/2 NPN (Sinking) Digital O/Ps |
|
|
| ZZ24D-ND-SR
|
2.4 GHz |
10 mW (Europe), 63 mW (rest of world) |
250 Kbps |
Up to 300 ft/Up to 1 mi |
-- |
15, 8 mS |
4/4/0/0 NPN (Sinking) Digital O/Ps |
|
|
| ZZ24D-NA-MR
|
2.4 GHz |
50 mW |
9600 bps |
Up to 600 ft/Up to 3 mi |
10 mi |
365, 56 mS |
2/2/2/2 PNP (Sourcing) Digital O/Ps |
|
|
| ZZ24D-NB-MR
|
2.4 GHz |
50 mW |
9600 bps |
Up to 600 ft/Up to 3 mi |
10 mi |
365, 56 mS |
4/4/0/0 PNP (Sourcing) Digital O/Ps |
|
|
| ZZ24D-NC-MR
|
2.4 GHz |
50 mW |
9600 bps |
Up to 600 ft/Up to 3 mi |
10 mi |
365, 56 mS |
2/2/2/2 NPN (Sinking) Digital O/Ps |
|
|
| ZZ24D-ND-MR
|
2.4 GHz |
50 mW |
9600 bps |
Up to 600 ft/Up to 3 mi |
10 mi |
365, 56 mS |
4/4/0/0 NPN (Sinking) Digital O/Ps |
|
|
| ZZ9D-NA-MR
|
900 MHz |
100 mW |
9600 bps |
Up to 1500 ft/Up to 7 mi |
20 mi |
365, 56 mS |
2/2/2/2 PNP (Sourcing) Digital O/Ps |
|
|
| ZZ9D-NB-MR
|
900 MHz |
100 mW |
9600 bps |
Up to 1500 ft/Up to 7 mi |
20 mi |
365, 56 mS |
4/4/0/0 PNP (Sourcing) Digital O/Ps |
|
|
| ZZ9D-NC-MR
|
900 MHz |
100 mW |
9600 bps |
Up to 1500 ft/Up to 7 mi |
20 mi |
365, 56 mS |
2/2/2/2 NPN (Sinking) Digital O/Ps |
|
|
| ZZ9D-ND-MR
|
900 MHz |
100 mW |
9600 bps |
Up to 1500 ft/Up to 7 mi |
20 mi |
365, 56 mS |
4/4/0/0 NPN (Sinking) Digital O/Ps |
|
|
ZZ9D-NA-LR
|
900 MHz |
1 mW (Europe), 1W (rest of world) |
115Kbps |
Up to 1500 ft/Up to 7 mi |
20 mi |
104, 9 mS |
2/2/2/2 PNP (Sourcing) Digital O/Ps |
|
|
| ZZ9D-NB-LR
|
900 MHz |
1 mW (Europe), 1W (rest of world) |
115Kbps |
Up to 1500 ft/Up to 7 mi |
20 mi |
104, 9 mS |
4/4/0/0 PNP (Sourcing) Digital O/Ps |
|
|
| ZZ9D-NC-LR
|
900 MHz |
1 mW (Europe), 1W (rest of world) |
115Kbps |
Up to 1500 ft/Up to 7 mi |
20 mi |
104, 9 mS |
2/2/2/2 NPN (Sinking) Digital O/Ps |
|
|
| ZZ9D-ND-LR
|
900 MHz |
1 mW (Europe), 1W (rest of world) |
115Kbps |
Up to 1500 ft/Up to 7 mi |
20 mi |
104, 9 mS |
4/4/0/0 NPN (Sinking) Digital O/Ps |
|
|
*UL Listed **NA and NB models have Sourcing Digital Outputs. NC and ND models have Sinking Digital Outputs. Note1. Latency figures between base units under good RF conditions. Add 45 mS per analog expansion moduel, add 25 mS per digtial expansion module.
Step 2. Choose I/O Modules to Expand
Each base module allows up to 6 expansion
units using the following modules.
| Digital Inputs (DI) | 0-48 VDC | ----- |
| Digital Outputs (DO)* | 10-45 VDC | NPN, PNP, Relays |
| Analog Inputs (AI) | 4-20 mA, 0-20 mA or 0-10 VDC | Selectable in software |
| Analog Outputs (AO) | 4-20 mA, 0-20 mA or 0-10 VDC | Selectable in software |
| RTD Temp Inputs (AI) | PT100, PT1000, CU | Selectable in software |
*Sinking (NPN) available upon request.
|
| Model Number |
Digital Inputs |
Digital Outputs |
Analog Inputs |
Analog Outputs |
|
Price |
ZZ-8DI-DC
|
8 |
---- |
---- |
---- |
|
|
| ZZ-8DO-T
|
---- |
8* PNP (Sourcing) |
---- |
---- |
|
|
| New! ZZ-8DO-T1
|
---- |
8* NPN (Sinking) |
---- |
---- |
|
|
| ZZ-4DI4DO-DCT
|
4 |
4* PNP (Sourcing) |
---- |
---- |
|
|
| New! ZZ-4DI4DO-DCT1
|
4 |
4* NPN (Sinking) |
---- |
---- |
|
|
| ZZ-4AI
|
---- |
---- |
4 |
---- |
|
|
ZZ-4AO
|
---- |
---- |
---- |
4 Passive source, requires isolated external power supply |
|
|
| New! ZZ-4AO-2
|
---- |
---- |
---- |
4 Active source, no external power supply required |
|
|
| ZZ-2AI2AO
|
---- |
---- |
2 |
2 |
|
|
| ZZ-8DO-R
|
---- |
8** |
---- |
---- |
|
|
New! ZZ-4RTD1
|
---- |
---- |
4*** |
--- |
|
|
*T=Transistor **R=Relay ***RTD Inputs
Step 3. Choose a Radio Modem
Get your data signals moving faster, farther, easier and cheaper.
- DIN rail mount saves panel space.
- Constant signal strength feedback - during installation and troubleshooting later.
- Rugged circuitry, wide temperature - for indoor and outside applications.
- Handles most industrial control power configurations and power supplies.
- Immediate integration into UL, CSA approved panels.
Use the table to make sure the
radio modem is compatible with
your chosen base module. More details on
radio modems from B&B Electronics.
| Base Module | Radio Modem Required |
| ZZ24D-NA-SR | ZP24D-250RM-SR |
| ZZ24D-NB-SR | ZP24D-250RM-SR |
| ZZ24D-NA-MR | ZP24D-96RM-MR |
| ZZ24D-NB-MR | ZP24D-96RM-MR |
| ZZ9D-NA-MR | ZP9D-96RM-MR |
| ZZ9D-NB-MR | ZP9D-96RM-MR |
| ZZ9D-NA-LR | ZP9D-115RM-LR |
| ZZ9D-NB-LR | ZP9D-115RM-LR |
|
Step 4. Choose Software and Accessories to complete your system.
Features
- New! Simplified programming software
- Basic screen and an advanced screen
- Auto search function if radio settings are forgotten
- Easy field firmware updates
Easy-to-program system! Zlinx radio modems and Zlinx Modbus I/O use the same software manager suite.
Configuration software is free (download software).
Or a CD can be purchased -- absolutely no registration fees or worries about installing it on any computer you have. |
Model No. |
Description |
Price |
DR-120-24
|
|
List Price: $99.00
Sale Price: $79.20
20% off through 12/31/09
|
|
New! ZZ-DIN1
|
Zlinx Modbus I/O - Spare DIN Mount Clip, Spring, 4 Screws
|
|
ZZ-PROG1-USB
|
|
|
New! ZZ-TB1
|
Zlinx Modbus I/O - Spare Terminal Block Kit, Dip Switch Cover
|
|
New! ZZ24D-ANT1
|
Zlinx Modubs I/O - Spare Antenna, 2.4 GHz
|
|
New! ZZ9D-ANT1
|